Power supply: DC power supply.
Output method: Relay output.
Inputs points: 12 points.
Outputs points: 8 points.Size: M18 (brass), single distance, non shield type.
Detection range: 10mm.
Connection mode: lead type (cable length is 2M and 5m two).
Thread length: Standard type.
Output type: NPN.
Action mode NC.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio
TP70-1S1
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site.
Simulation test was carried out in the environment of high oil mist concentration. Actuator: Roller plunger.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Input capacity: 16 points.
Internal I/O common: PNP.
ON voltage: 15 VDC min. (between each in,
put terminal and the G terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the G terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
TP70-1S1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=TP70-1S1&select=5