Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 3.0A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red).
Main functions: Ion balance adjustment (Automatic and manual)
SGE-245-0-1890L 05000C-05000C
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0.1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 2 kg (Approx. 3 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, Stand, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Size: M18 (brass), single distance, non shield type.
Detection range: 10mm.
Connection mode: lead type (cable length is 2M and 5m two).
Thread length: long thread type.
Output type: NPN.
Action mode NC.
Set up the new standard of the world economy proximity sensor.
OMRON as a pioneer and leader in proximity sensor industry,
Now bring you a new E2B proximity sensor with high performance to price ratio.
This series of products are complete,
Aimed at reasonable prices to meet customer demand for high quality and high reliability of the sensor.
We have tested the product not only on the protection level (IP67) specific item,
The oil spray test was carried out on the condition of the work site.
Simulation test was carried out in the environment of high oil mist concentration.
SGE-245-0-1890L 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-245-0-1890L 05000C-05000C&select=5