Terminal: Screw terminal (-B).
Actuator: Short hinge roller lever.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it.
Same shape and mounting procedures as the Z Basic Switches. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action)
SGE-225-0-0560 05000C-05000C
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Power ratings: 120 W.
Rated input voltage: 100 to 240 VAC .
(allowable range: 85 to 264 VAC or 90 to 350 VDC).
Rated output voltage: 24 V.
Rated output current: 5 A.
Maximum boost current: 6 A.
A Perfect Fit for Small Control Panels.
Coated PCBs for Better Resistance to Environment.
Connections for Easy Wiring.
Operation possible at ambient temperatures from -40 to 70°C.
DC input supported (90 to 350 VDC).
Power Boost function at 120%.
Horizontal side-by-side mounting.
Vibration resistance to 5G, and 300-VAC abnormal,
input voltage supported for 1 second.
Complies with EN/IEC 61558-2-16.
UL 508 Listing/UL 1310 Class 2 output standards *1,
ANSl/ISA 12.12.01.
Certification for 3,000 m altitude,
(UL/EN/IEC 60950-1 and EN 50178).
Lloyd’s, DNV GL *2.
Conforms to F47-0706.
Five years Warranty *3. Setting range: 20 to 200 V AC/DC, 30 to 300 V AC/DC, 60 to 600 V AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Voltage Monitoring for.
Industrial Facilities and Equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 5 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
SGE-225-0-0560 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-0560 05000C-05000C&select=5