Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
SGE-125-0-0420 05000C-05000C
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Achieve Safety Control through,
Programming.
Compact Safety Controller.
The NE1A-SCPU01-V1 provides 16 built-in safety inputs,
and 8 built-in safety outputs.
The NE1A-SCPU02 provides 40 built-in safety inputs and,
8 built-in safety outputs.
Reduced wiring with safety networks. Connect up to 32,
Safety Terminals.
Monitor the safety system from Standard Controllers,
across the network.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification. For 8-slot Backplane.Ratings: 1 A at 30 VDC.
LED indicator: With indicator.
Actuator: Sealed pin plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center roller lever models that enable ganged mounting.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models.) Name: Safety Controller.
Number of I/O: Safety inputs, 20; Test outputs, 6;
Safety outputs, Solid-state outputs: 8; Standard outputs, --.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats.
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified.
SGE-125-0-0420 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-125-0-0420 05000C-05000C&select=5