Brand: OMRON
Product model: ZX1-LD100A66
Name: Smart Sensors
Sort: User's Manual
File language: English
File size: 3.33MB
Power supply: DC.
Output type: PNP.
For the most recent information on models that have been,
certified for safety standards, refer to your OMRON website. Nozzle gap.
Optical system: positive and negative radiation.
Detection distance: 10 positive and negative 0.5mm.
Beam shape: linear beam.
Beam diameter: 900mm * 25 M ZX1-LD100A66 User's Manual.
Resolution: 0.25 M.
Cable length: 2m. Power supply voltage: DC24V ZX1-LD100A66
Control output: PNP output. Sensor that can be connected: Thermo-Humidity Sensor Head (ZN-THS1__-S).
Display: LCD 7-segment 5-digit 2-step display,
auxiliary information indicator display.
Measurement interval: 10 s, 20 s, 30 s, 1 min, 2 min,
5 min, 10 min, 20 min, 30 min, 1 h.
Calculation function: Instantaneous value, maximum value,
minimum value, average value ZX1-LD100A66 User's Manual.
Operating mode: Normal mode, sleep mode.
Recording mode: Continue, ring.
Alarm signal output: Output to photocoupler (External power supply: 12 to 24 VDC,
Load current: Max. 45 mA) Alarm hold setting is possible.
Internal storage device: Internal memory: Approx. 8,500 data items.
External storage device: SD card (to save measured values and to save/read set, values),Recommended SD card: HMC-SD291 (manufactured by OMRON) ZX1-LD100A66 User's Manual.
Power supply voltage: DC input: 24 VDC±10%, Battery: 2 AAA batteries.
Battery life: Approx. 1 year∗6 (sleep mode, measurement interval of 10 minutes, with 2 AAA nickel metal hydride batteries, with SD card not inserted).
Operating temperature range: 0 to 60°C.
Operating humidity range: 20 to 85% (no condensation).
Weight (packaged): Approx. 500 g.
Accessories: Instruction Sheet, Startup Guide CD-ROM∗7,
Alarm output connector∗8, DC cable (straight type).
Easy temperature and humidity control with an SD Card. Category: option.
Shape: data recording instrument for temperature measurement.
Return correctiion ZX1-LD100A66 Manual.
Strong support for all field measurements.
Ease of full channel insulation, support multi function input.
Max 200CH scalability (ZR-RX45).
Simple LAN connection (ZR-RX45/ZR-RX70). "Optical system: positive and negative radiiation ZX1-LD100A66 Manual.
Detection distance: 20 positive and negative 1mm.
Beam shape: linear beam.
Beam diameter: 900mm * 25 M.
Resolution: 0.25 M.
Cable length: 0.5m.
Related products
OMRON
Smart Sensor
ZX1-LD50A81 5M
OMRON Smart Sensor ZX1-LD50A81 5M
Connection method: Pre-wired. Cale length:
OMRON
Smart Sensor
ZX1-LD50A61 2M
OMRON Smart Sensor ZX1-LD50A61 2M
Connection method: Pre-wired. Cale length:
OMRON
Smart Sensor
ZX1-LD300A61 2M
OMRON Smart Sensor ZX1-LD300A61 2M
Connection method: Pre-wired. Cale length:
OMRON
Smart Sensor
ZX1-LD50A81 2M
OMRON Smart Sensor ZX1-LD50A81 2M
Connection method: Pre-wired. Cale length: