Input voltage: DC10-60V.
Output current: 20 A.
Contribute to build high reliable systems.
Compact and Cost-effective solution.
for Back-up applications.
Easy setup for system reliability.
requirement.
Redundancy operating LED for the status confirmation.
A signal output for failure detection of power supplies SDV-DH2 User's Manual.
By adjusting the power supply voltage to light up Balance LED,
the lifetime of power supplies will be more than twice
SDV-DH2
Wide range input.
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20).
Wide operation temperature range: -40 to 70 °C.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1 Lloyd''s standards *2.
EMS: EN61000-6-2.
EMI: EN61000-6-3.
Six years warranty *3 SDV-DH2 User's Manual. Power rating: 200 W.
Input voltage: 100 to 120 VAC, 200 to 240 VAC (allowable range: 90 to 132 VAC,
180 to 264 VAC, or 254 to 373 VDC(Select with the switch.)*2).
Output voltage: 12 V VDC.
Output current: 17 A.
Built-in fan: None.
Model with terminal block facing upward.
High Reliability at a Reasonable Cost.
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation SDV-DH2 User's Manual.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life. A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models).
Easy mounting to DIN Rails with Mounting Brackets (sold separately).
Refer to Period and Terms of W. Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 15W.
Output voltage: 24V.
Output current: 0.65A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Suppport finger touch protection to prevent electric shock SDV-DH2 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer SDV-DH2 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"