File size: 0.87MB
Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3.8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability S8TS-03012F-E1 EtherCAT Connection Guide.
240- and 480-W power supplies with and digital circuit,
protectors in a single package S8TS-03012F-E1
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature).
Conforms to UL Class 2 S8TS-03012F-E1 EtherCAT Connection Guide.
Mounts to DIN Rail. Power ratings: 7.5 W.
Output voltage: 12 V.
Output current: 0.6 A.
Miniature DIN Rail Mounting DC-DC Power.
Supplies.
65 mm depth enables mounting onto control panels with.
100 mm depth.
Inputs: 10.2 to 27.6 VDC (DC input).
7.5-W models provide both ±12-V and ±15-V outputs.
A complete lineup with 10 different models.
UL and CSA approved.
RoHS-compliant. Type: open type S8TS-03012F-E1 EtherCAT Connection Guide.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 15V.
Output current: 7A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock S8TS-03012F-E1 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer S8TS-03012F-E1 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
Related products
OMRON
Switch Mode Power Supply
S8TS-03012F
OMRON Switch Mode Power Supply S8TS-03012F
Output voltage: 12 V. Output current: 2.5 A.
OMRON
Switch Mode Power Supply
S8TS-03012-E1
OMRON Switch Mode Power Supply S8TS-03012-E1
Output voltage: 12 V. Output current: 2.5 A.
OMRON
Switch Mode Power Supply
S8TS-03012F-E1
OMRON Switch Mode Power Supply S8TS-03012F-E1
Output voltage: 12 V. Output current: 2.5 A.
OMRON
Switch Mode Power Supply
S8TS-03012
OMRON Switch Mode Power Supply S8TS-03012
Output voltage: 12 V. Output current: 2.5 A.