Power ratings: 180 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 7.5 A.
Alarm output *2: Sinking.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication S8JX-G05012 Connection Guide.
Monitor and Simple Functions for.
Easy System Commissioning
S8JX-G05012
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) S8JX-G05012 Connection Guide.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 24V.
Output current: 14A peak current 16.5A (AC200V).
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device S8JX-G05012 Connection Guide.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Supportt finger touch protection to prevent electric shock S8JX-G05012 Manual.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer S8JX-G05012 Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"