OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON S8EX-BP10024 Manual S8EX-BP10024 Connection Guide

OMRON S8EX-BP10024 Manual S8EX-BP10024 Connection Guide

Brand: OMRON
Product model: S8EX-BP10024
Name: Digital Controller
Sort: Connection Guide
File language: English
File size: 0.46MB
Prevents Equipment Stoppage, Data Loss,
and Other Problems Resulting from Momentary.
Power Failures.
Provides a backup time of 500 ms at an output current of 2.5 A.
Can be wired to the 24-V output from the S8VS Supplies.
Connects to an S8TS Power Supply via an S8T-BUS03 Bus Line Connector.
Parallel connections to up to four Blocks can be used to increase,
the backup time and current capacities S8EX-BP10024 Connection Guide S8EX-BP10024
Complies with SEMI F47-0200 standard.
RoHS-compliant.
Ambient operating temperature range of –20 to 60°C. Control power supply voltage: 24 VDC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring S8EX-BP10024 Connection Guide.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T) S8EX-BP10024 Connection Guide.
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 11 mm.
External diameter of cable: Min, 9 mm; Max, 11 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC)*1.
Output voltage: 24 V.
Output current: 2.5 A.
Alarm output *2: --.
UL Class 2 Output standards: Yes.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output staandards S8EX-BP10024 Manual.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) S8EX-BP10024 Manual.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Switch Mode Power Supply
S8EX-BP10012
OMRON Switch Mode Power Supply S8EX-BP10012
Power ratings: 100 W. Output voltage: 12 V.
OMRON
Switch Mode Power Supply
S8EX-BP24036
OMRON Switch Mode Power Supply S8EX-BP24036
Power ratings: 240 W. Output voltage: 36 V.
OMRON
Switch Mode Power Supply
S8EX-BP15024
OMRON Switch Mode Power Supply S8EX-BP15024
Power ratings: 150 W. Output voltage: 24 V.
OMRON
Switch Mode Power Supply
S8EX-BP05005L
OMRON Switch Mode Power Supply S8EX-BP05005L
Power ratings: 50 W. Output voltage: 5 V. O