OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K8AC-H13PT-FLK Manual K8AC-H13PT-FLK Communications Manual

OMRON K8AC-H13PT-FLK Manual K8AC-H13PT-FLK Communications Manual

Brand: OMRON
Product model: K8AC-H13PT-FLK
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 7.32MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K8AC-H13PT-FLK Communications Manual K8AC-H13PT-FLK
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 32Control supply voltage: 110 VAC; With voltage fluctuation compensation K8AC-H13PT-FLK Communications Manual.
Operating current: 4 to 10 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out K8AC-H13PT-FLK Communications Manual.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated frrom the start of operation K8AC-H13PT-FLK Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AC-H13PT-FLK Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Digital Heater Element Burnout Detector
K8AC-H13PC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H13PC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H12PT-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H12PT-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H11PC-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H11PC-FLK
Power supply voltage: 100 to 240 VAC. Heater
OMRON
Digital Heater Element Burnout Detector
K8AC-H13CT-FLK
OMRON Digital Heater Element Burnout Detector K8AC-H13CT-FLK
Power supply voltage: 100 to 240 VAC. Heater