OMRON K3HB-XAD-FLK1AT11 Manual K3HB-XAD-FLK1AT11 Communications Manual

Brand: OMRON
Product model: K3HB-XAD-FLK1AT11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.07MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V K3HB-XAD-FLK1AT11 Communications Manual.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-XAD-FLK1AT11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Can rotate the encoder and a variety of ON/OFF pulse signal, the highest speed up to 50kHzRated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC K3HB-XAD-FLK1AT11 Communications Manual.
Ideal for monitoring 3-phase power supplies.
for industrial facilities and equipment.
Monitor overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase 3-wire or 4-wire power supplies with,
just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power,
supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Output overvoltages and undervoltages using separate relays K3HB-XAD-FLK1AT11 Communications Manual.
World-wide power specifications supported by one Unit,
(switchable).
Output status can be monitored using LED indicator. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-XAD-FLK1AT11 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-XAD-FLK1AT11 Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PNB-FLK1AT11 AC/DC24V
OMRON Time interval table K3HB-PNB-FLK1AT11 AC/DC24V
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RNB-FLK1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RPB-FLK1AT11 AC/DC24V
OMRON Rotating pulse meter K3HB-RPB-FLK1AT11 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RPB-FLK1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK1AT11 AC100-240
Input type: PNP input type. Event input term