OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-VLC Manual K3HB-VLC User's Manual

OMRON K3HB-VLC Manual K3HB-VLC User's Manual

Brand: OMRON
Product model: K3HB-VLC
Name: Digital Temperature Controllers
Sort: User's Manual
File language: English
File size: 2.28MB
Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-VLC User's Manual.
High-precision heater burnout alarm with digital measurement K3HB-VLC
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@) K3HB-VLC User's Manual. Type: High-sensitivity models.
Sensed current: 30 mA (fixed).
Type: High-speed models.
Operating time: Less than 0.1 s.
Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-voltage circuits due to the deterioration of insulation in,
electrical devices.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads K3HB-VLC User's Manual.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutually compatible.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease. Measuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undeervoltages K3HB-VLC Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-VLC Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Timer Interval Indicator
K3HB-P Series
OMRON Timer Interval Indicator K3HB-P Series
Digital Time Interval Meter for Measuring. P
OMRON
Time interval table
K3HB-PNB-L2AT11 AC100-240
OMRON Time interval table K3HB-PNB-L2AT11 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Rotating pulse meter
K3HB-RPB-FLK3AT11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-FLK3AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Rotating pulse meter
K3HB-RNB-FLK1AT11 AC100-240
OMRON Rotating pulse meter K3HB-RNB-FLK1AT11 AC100-240
Input type: NPN/ voltage pulse input type. E