OMRON K3HB-SSD-CPAC11 Manual K3HB-SSD-CPAC11 Communications Manual

Brand: OMRON
Product model: K3HB-SSD-CPAC11
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 2.28MB
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V K3HB-SSD-CPAC11 Communications Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-SSD-CPAC11
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable from 10msCategory: external supply 100mA DC5V type K3HB-SSD-CPAC11 Communications Manual.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-SSD-CPAC11 Communications Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be appliedMeasuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltagges K3HB-SSD-CPAC11 Manual.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K3HB-SSD-CPAC11 Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.
Related products
OMRON
Voltage and current panel meter
K3HB-XVD-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XVD-CPAC11 AC100-240
Input type: DC voltage input type. Output ty
OMRON
Rotating pulse meter
K3HB-RPB-CPAC11 AC100-240
OMRON Rotating pulse meter K3HB-RPB-CPAC11 AC100-240
Input type: PNP input type. Event input term
OMRON
Voltage and current panel meter
K3HB-XAD-CPAC11 AC100-240
OMRON Voltage and current panel meter K3HB-XAD-CPAC11 AC100-240
Input type: DC current input. Output type: r
OMRON
Time interval table
K3HB-PNB-CPAC11 AC/DC24V
OMRON Time interval table K3HB-PNB-CPAC11 AC/DC24V
Input type: NPN/ voltage pulse input type. E