Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 32 to 80 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K3HB-SSD User's Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K3HB-SSD
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K3HB-SSD User's Manual. Standard function model: detection of under voltage.
Appearance: ADR shell.
Open circuit: voltage, no voltage, DC circuit breaker.
Rated voltage: AC110V.
Rated frequency: 50/60Hz.
Voltage adjustment range: 60-65-70-75-80-85-90-95-100V (9 shunt).
Time hopping: timing; 0.1-0.2-0.4-0.6-0.8-1.0-1.2-1.4-1.6-1.8-2.0s (11 shunt).
Control power supply: and input common K3HB-SSD User's Manual.
Rated consumption VA:7VA.
Control output: 1C, 1A closed 110V 15A1000 L/R=0ms times (DC);
Open 110V 1A DC 1000 (L/R=25ms).
Display: display resolution 1V (display range: 50-130V).
Automatic experiment: there.
Quality: about 1kg.
External: Mount Searl N1.5.
Digital voltage relay series.
K2VU-H/K2VA-H type, large range of adjustment shunt,
Easy to coordinate digital VR.
And the automatic tester with convenient for relay testing.
Measurable voltage value.
The reliability can be improved by monitoring the function at any time.
The forced action of the experimental switch can be easily recognized.
Exterior dimension based on DIN standard,
The depth is only the size of the 88.5mm (terminal except). Input type: DC voltage/current.
Supply voltage: 100 to 240 VAC.
Comparative Output Model: 2 relay contact outputs (SPST-NO).
Highly Visible LCD Display with 2-color,
(Red and Green) LEDs.
Multi-range DC voltage/current input.
Front-panel key operation for easy setting.
Average processing function suppresses flicker.
Scaling, frontt-panel forced-zero, zero-limit functions K3HB-SSD Manual.
Easy confirmation of max/min display.
Short 80-mm depth (measured from edge of face plate).
Finger protective cover (standard equipment) guards against electric shock.
Water- and dust-pproof NEMA4X (IP66 equivalent) front panel K3HB-SSD Manual.
Recognized to U.S. and Canadian requirements under the Component,
Recognition Program of UL.
CE marking.