Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K3HB-HTA-DRT1 Communications Manual K3HB-HTA-DRT1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event inputMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC K3HB-HTA-DRT1 Communications Manual.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervoltages.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load) K3HB-HTA-DRT1 Communications Manual.
Process control signal (0 to 10 V) and current splitter input supported.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. 1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red.
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side:: 0 to 1 A or 0 to 5 A) K3HB-HTA-DRT1 Manual.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can bbe switched between normally open and normally closed K3HB-HTA-DRT1 Manual.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
Related products
OMRON
Voltage and current panel meter
K3HB-XVA-DRT1 AC100-240
OMRON Voltage and current panel meter K3HB-XVA-DRT1 AC100-240
Type of input: AC voltage input. Output type
OMRON
Temperature panel
K3HB-HTA-L1AT11 AC100-240
OMRON Temperature panel K3HB-HTA-L1AT11 AC100-240
Type of input: platinum resistance / thermoco
OMRON
Time interval table
K3HB-PNB-A-DRT1 AC100-240
OMRON Time interval table K3HB-PNB-A-DRT1 AC100-240
Input type: NPN/ voltage pulse input type. E
OMRON
Temperature panel
K3HB-HTA-CPAC11 AC/DC24
OMRON Temperature panel K3HB-HTA-CPAC11 AC/DC24
Type of input: platinum resistance / thermoco