OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON K2CM-Q2LAV Manual K2CM-Q2LAV Communications Manual

OMRON K2CM-Q2LAV Manual K2CM-Q2LAV Communications Manual

Brand: OMRON
Product model: K2CM-Q2LAV
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 0.29MB
Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K2CM-Q2LAV Communications Manual K2CM-Q2LAV
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mInput type: NPN/ voltage pulse input type K2CM-Q2LAV Communications Manual.
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Relay contact: OUT5; OUT31c, OUT4, OUT2, OUT1: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display K2CM-Q2LAV Communications Manual.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
Cumulative pulse input is 50kHz, phase difference pulse is 25kHz, increase or decrease of pulse is 30kHzTime specification: Inverse type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicateed from the start of operation K2CM-Q2LAV Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K2CM-Q2LAV Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Motor Protective Relay
K2CM-Q2L
OMRON Motor Protective Relay K2CM-Q2L
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-2L
OMRON Motor Protective Relay K2CM-2L
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q2HV
OMRON Motor Protective Relay K2CM-Q2HV
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q2LSA
OMRON Motor Protective Relay K2CM-Q2LSA
Time specification: Instantaneous type. Curre