OMRON K2CM-1LA Manual K2CM-1LA Communications Manual

Brand: OMRON
Product model: K2CM-1LA
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 0.29MB
Input type: high speed response type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: DeviceNet; -; DeviceNet.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K2CM-1LA Communications Manual K2CM-1LA
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL standard for recognitionMeasuring voltage: 6 to 60 mV AC/DC, 10 to 100 mV AC/DC, 30 to 300 mV AC/DC K2CM-1LA Communications Manual.
Supply voltage: 200-230 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages or undervoltages.
Manual resetting and automatically resetting supported by one Relay.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Process control signal (0 to 10 V) and current splitter input supported K2CM-1LA Communications Manual.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because opperation time,
is indicated from the start of operation K2CM-1LA Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K2CM-1LA Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Motor Protective Relay
K2CM-1M
OMRON Motor Protective Relay K2CM-1M
Time specification: Inverse type. Current set
OMRON
Motor Protective Relay
K2CM-Q2M
OMRON Motor Protective Relay K2CM-Q2M
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-Q1LS
OMRON Motor Protective Relay K2CM-Q1LS
Time specification: Instantaneous type. Curre
OMRON
Motor Protective Relay
K2CM-2HAV
OMRON Motor Protective Relay K2CM-2HAV
Time specification: Inverse type. Current set