OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON H5S-YA4-X Manual H5S-YA4-X User's Manual

OMRON H5S-YA4-X Manual H5S-YA4-X User's Manual

Brand: OMRON
Product model: H5S-YA4-X
Name: Digital Controllers
Sort: User's Manual
File language: English
File size: 1.18MB
Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000.0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits H5S-YA4-X User's Manual.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 H5S-YA4-X0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Supply voltage: 24 VAC; 12, 24 VDC.
Time-limit contact: SPDT.
Short-time range model (0.1 s to 10 min).
Ultra-slim Timer for G2R Relay Socket.
Pin configuration compatible with G2R Relay and mounts to the,
P2R/P2RF Socket H5S-YA4-X User's Manual.
Standard multiple time ranges and multiple operating modes.
Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Volt,
age, and EMC Directives. Miniature DIN-sized (48 x 48 mm) Quartz.
Timer with Abundant Series Versions.
Series version cover a wide range of rated times; 9.999 s,
99.99 s, 999.9 s, 99 min 59 s, and 99 hrs 59 min.
Selection of elapsed time indication, remaining time indication,
contact output, and transistor output types to suit requirements H5S-YA4-X User's Manual.
Power supply freely selectable within a range of 100 to,
240 VAC, as well as 12 to 48 VDC.
Certified for UL and CSA safety standards. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
ZZ: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H5S-YA4-X Manual.
External connections: 8-pin socket.
Input: Signal, Reeset (NPN input) H5S-YA4-X Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Digital timing switch
H5S-WA2D
OMRON Digital timing switch H5S-WA2D
Control cycle: a week. Output numer: 2 chann
OMRON
Digital Time Switch
H5S-YFB4-X
OMRON Digital Time Switch H5S-YFB4-X
Control cycle: Yearly. Numer of outputs: 4
OMRON
Digital Time Switch
H5S-YFB4D-X
OMRON Digital Time Switch H5S-YFB4D-X
Control cycle: Yearly. Numer of outputs: 4
OMRON
Digital timing switch
H5S-WFA2
OMRON Digital timing switch H5S-WFA2
Control cycle: a week. Output numer: 2 chann