Type: Standard.
Sealing: Flux-tight.
Poles: 4 poles.
Contact configuration: 3PST-NO, SPST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN50205 Class A, certified by VDE).
Supports the CE marking of machinery (Machinery Directive) GT1-OD32ML-1 HOST CONNECTION MANUAL.
Helps avoid hazardous machine status when used as part of,
an interlocking circuit
GT1-OD32ML-1
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangement simplifies PWB pattern design.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard GT1-OD32ML-1 HOST CONNECTION MANUAL.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated GT1-OD32ML-1 HOST CONNECTION MANUAL.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phasee heaters GT1-OD32ML-1 Manual.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) GT1-OD32ML-1 Manual.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.