Terminal (wire connection): Push-In Plus Terminal.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 230V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel G9SX-SM032-RT USER'S MANUAL.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals
G9SX-SM032-RT
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires G9SX-SM032-RT USER'S MANUAL.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range G9SX-SM032-RT USER'S MANUAL.
Maximum input pulse frequency of 4MHz,
(Line driver input after quadrature).
High-speed network EtherCAT enables,
high-speed and accurate control.
Selectable two input types:
Open collector input and line driver input.
Built-in two external latch inputs,
and one reset input.
Selectable node address settings: setting with,
rotary switches and setting on tool software.
Detachable screw terminal will facilitate,
the maintenance work. Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 5000mm; B, 4750mm.
Input use.
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, 4PST-NO; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combiningg,
the Relay with an Auxiliary Contact Block G9SX-SM032-RT Manual.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% thhe volume of a standard electromagnetic contactor,
to help downsize control panels G9SX-SM032-RT Manual.
According to OMRON investigation of IIEC-AC1 50 A specifications.