Home >> Download >> OMRON >> Manual Download >> OMRON EJ1G-HFUB-NFL2 Manual EJ1G-HFUB-NFL2 OPERATION MANUAL

OMRON EJ1G-HFUB-NFL2 Manual EJ1G-HFUB-NFL2 OPERATION MANUAL

Brand: OMRON
Product model: EJ1G-HFUB-NFL2
Name: Temperature Controller
Sort: OPERATION MANUAL
File language: English
File size: 4.73MB
Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. E3JM-DS70M4 detection method: diffuse reflection type,
Connection: terminal plate,
Detection range: 700mm EJ1G-HFUB-NFL2 OPERATION MANUAL.
Output status: ON into the light; light shading ON; switch conversion type EJ1G-HFUB-NFL2
Output: relay.
2 types of cost reductionSize: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function EJ1G-HFUB-NFL2 OPERATION MANUAL.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure EJ1G-HFUB-NFL2 OPERATION MANUAL.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and dellay) to set the implementation of flexible contact output EJ1G-HFUB-NFL2 Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internnal relay of the temperature controller EJ1G-HFUB-NFL2 Manual. Slit width: Width 0.5, 1 × 13.4 mm.
Installation procedure: Seal type.
Applicable type: E32-T16P, E32-T16PR.