Output configuration: DC switching NPN (normally open or closed selectable).
Sensing method: Through-beam.
Sensing distance: 50 cm.
Capable of Setting the Sensing Range.
Using an Ultrasonic Beam.
Ensures the stable detection of a variety of objects,
regardless of the color, transparency, or material E5GN Series User's Manual.
(metallic or non-metallic) of the objects.
Limits the ultrasonic beam width to 8°, thus,
detecting minute objects as small as 2 x 2 cm
E5GN Series
Detects objects smoothly while largely suppressing,
interference from background objects.
Sealed to resist dust and dirt and emits ultrasonic,
waves at a frequency of approximately 200 kHz,
thus providing high immunity from impact and,
environmental noise E5GN Series User's Manual. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Lead wire length: 1 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5GN Series User's Manual.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: 4-loop control .
Control mode: 4-loop standard control, 2-loop heating and cooling control.
Outputs(control/transfer): 4 points: Current output (4 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, RS-485.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E5GN Series Basic Type Manual. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation) E5GN Series Basic Type Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.