OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5GC-CX2ACM-015 Manual E5GC-CX2ACM-015 Advanced Type

OMRON E5GC-CX2ACM-015 Manual E5GC-CX2ACM-015 Advanced Type

Brand: OMRON
Product model: E5GC-CX2ACM-015
Name: OMRON E5GC-CX2ACM-015 Manual E5GC-CX2ACM-015 Advanced Type
Sort: Advanced Type
File language: English
File size: 6.47MB
Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output configuration: DC 2-Wire Models.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available E5GC-CX2ACM-015 Advanced Type. Case color: Black.
Control output: Voltage output (for driving SSR) E5GC-CX2ACM-015
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5GC-CX2ACM-015 Advanced Type.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5GC-CX2ACM-015 Advanced Type.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5GC-CX2ACM-015 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5GC-CX2ACM-015 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Digital temperature controller
E5GC-CX2A6M-016
OMRON Digital temperature controller E5GC-CX2A6M-016
Size: 48 x 24mm. Control output 1: linear cu
OMRON
Digital temperature controller
E5GC-CX2D6M-000
OMRON Digital temperature controller E5GC-CX2D6M-000
Size: 48 x 24mm. Control output 1: linear cu
OMRON
Digital temperature controller
E5GC-CX2ACM-000
OMRON Digital temperature controller E5GC-CX2ACM-000
Size: 48 x 24mm. Control output 1: linear cu
OMRON
Digital temperature controller
E5GC-CX1D6M-015
OMRON Digital temperature controller E5GC-CX1D6M-015
Size: 48 x 24mm. Control output 1: linear cu