Size: M8(Stainless steel)(See note 2.); Double; Unshielded.
Sensing distance: 4 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black E5EZ-C3MTD User's Manual.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output E5EZ-C3MTD
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type E5EZ-C3MTD User's Manual.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors E5EZ-C3MTD User's Manual.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperatture Sensors E5EZ-C3MTD Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EZ-C3MTD Manual.
Related products
OMRON
Digital Temperature Controllers
E5EZ-Q3HMTD
OMRON Digital Temperature Controllers E5EZ-Q3HMTD
Size: 1/8 DIN 48 × 96 × 78 W × H × D. Power
OMRON
Digital Position-Proportional Controllers
E5EZ-PRR201L
OMRON Digital Position-Proportional Controllers E5EZ-PRR201L
Size: 1/8DIN 48 × 96 × 78 W × H × D. Power
OMRON
Thermostat
E5EZ-C3HMT
OMRON Thermostat E5EZ-C3HMT
Type: controller with terminal locks. Size:
OMRON
Digital Position-Proportional Controllers
E5EZ-PRRL
OMRON Digital Position-Proportional Controllers E5EZ-PRRL
Size: 1/8DIN 48 × 96 × 78 W × H × D. Power