E32-C41 type: special beam; Coaxial / spot,
Specialty: long distance small spot,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSize: M18 (brass), single distance, non shield type.Size: 96 x 96mm.
Ontology: terminal type, temperature input type E5ER-Q4B User's Manual.
Type: control output 1 point type (power AC/DC24V)
E5ER-Q4B
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: - E5ER-Q4B User's Manual.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5ER-Q4B User's Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V.
Input type: thermocouple.
Alarm points: -.
Control output: voltage output (for driving SSR).
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple.
Sampling time was reduced to 250ms. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checkk the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5ER-Q4B Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5ER-Q4B Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.