Appearance: M5.
Sensing distance: 3 mm.
Connecting method: M8 Connector Models.
Cable specifications: --.
Operation mode: Nc.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 E5EN-R3MT-500 User's Manual. 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
E5EN-R3MT-500
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) E5EN-R3MT-500 User's Manual.
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Water- and Oil-resistant.
Photoelectric Sensor with.
Metal Housing Used for Long.
range Sensing.
Excellent resistance against the water and oil.
Easy application in locations with oil mist.
Long-range sensing up to 30 m with Through-beam models.
Shock resistance rated at 1,000m/s2 E5EN-R3MT-500 User's Manual.
Product lineup includes metal M12 pre-wired connector models.
NPN/PNP selector switch output. Sensing method: Through-beam type.
Sensing distance(slot width): 3.6 mm.
Output type: NPN output.
Output configuration: Light-ON.
Cable length: 1 m.
Photomicrosensor with built-in,
amplifier and attached cable reduces,
external light interference.
Light modulation effectively reduces external light interference.
Wide operation voltage range: 5 to 24 VDC.
Easy operation monitoring with bright light indicator. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performaance improvement E5EN-R3MT-500 Basic Type Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5EN-R3MT-500 Basic Type Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.