Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 4.04MB
Control output: voltage output (SSR driver).
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: 1 points.
Communication: -.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V E5EN-QY3BT-N User's Manual.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E5EN-QY3BT-N
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E5EN-QY3BT-N User's Manual.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete E5EN-QY3BT-N User's Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm). E3JK-R91J regression reflection type,
E3JK communication type: mode; shading ON,
Miniature amplifier built-in type photoelectric switchCase color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-Q1TC;
Resistance thermometer input, E5GN-Q1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-QY3BT-N Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-QY3BT-N Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Foundation type temperature controller
E5EN-CY3BT-N
OMRON Foundation type temperature controller E5EN-CY3BT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-Q3HT-N
OMRON Foundation type temperature controller E5EN-Q3HT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-Q3HBTD-N
OMRON Foundation type temperature controller E5EN-Q3HBTD-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-Q3HL-N
OMRON Foundation type temperature controller E5EN-Q3HL-N
Size: 48 x 96mm. Ontology: terminal type, ana