Size: M12 (Brass); Single; Shielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Control output: Relay output.
Auxiliary output: --.
Communications: RS-485.
Heater burnot: -- E5EN-HTAA2HH03BD-FLK User's Manual.
Event inputs: --.
Power supply voltage: 24 VAC/VDC
E5EN-HTAA2HH03BD-FLK
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance E5EN-HTAA2HH03BD-FLK User's Manual.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel E5EN-HTAA2HH03BD-FLK User's Manual. Appearance: Standard Models, Unshielded 34 dia.
Sensing distance: 25 mm [3 to 25 mm *].
Model: Output configuration, AC 2-wire;
Operation mode, NC.
Long-distance Capacitive Sensor.
with Adjustable Sensitivity.
CE Marking for DC 3-wire models and AC/DC 2-wire models.
Noise-resistant models are also available for environments with,
strong noise. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperatture Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-HTAA2HH03BD-FLK Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-HTAA2HH03BD-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.