OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5EN-HTAA2HH01BD-FLK Basic Type Manual E5EN-HTAA2HH01BD-FLK Basic Type

OMRON E5EN-HTAA2HH01BD-FLK Basic Type Manual E5EN-HTAA2HH01BD-FLK Basic Type

Brand: OMRON
Product model: E5EN-HTAA2HH01BD-FLK
Name: E5EN-HTAA2HH01BD-FLK Basic Type OMRON E5EN-HTAA2HH01BD-FLK Basic Type Manual
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5EN-HTAA2HH01BD-FLK Basic Type E5EN-HTAA2HH01BD-FLK
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5EN-HTAA2HH01BD-FLK Basic Type.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E5EN-HTAA2HH01BD-FLK Basic Type. , can be a key operation. The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performancee improvement E5EN-HTAA2HH01BD-FLK Basic Type Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5EN-HTAA2HH01BD-FLK Basic Type Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
High performance temperature controller
E5EN-HSS2HH01BD-FLK
OMRON High performance temperature controller E5EN-HSS2HH01BD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5EN-HTAA2HH03BD-FLK
OMRON Programmed temperature controller E5EN-HTAA2HH03BD-FLK
Size: 48 x 96mm. Type: power AC/DC24V with. S
OMRON
Programmed temperature controller
E5EN-HTAA2HHBF
OMRON Programmed temperature controller E5EN-HTAA2HHBF
Size: 48 x 96mm. Category: power AC100 240V
OMRON
High performance temperature controller
E5AN-HSS2HH01BD-FLK
OMRON High performance temperature controller E5AN-HSS2HH01BD-FLK
Size: 96 x 96mm. Type: power AC/DC24V with. S