Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: voltage output (for driving a bidirectional thyristor switching element).
Input: thermocouple.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input E5EN-HAA2HH03B-FLK User's Manual
E5EN-HAA2HH03B-FLK
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions. Model: Shielded, M30.
Sensing distance: 10 mm.
Output configuration: DC 3-wire, NPN E5EN-HAA2HH03B-FLK User's Manual.
Model: Operation mode, NO.
Proximity Sensor with Resin Case,
with Superb Water Resistance.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Appearance: Shielded, M18.
Sensing distance: 8 mm.
Output configuration: DC 2-wire (no polarity) (3)-(4) pin arrangement.
Operation mode: NO.
Spatter-resistant Fluororesin,
coated Proximity Sensor E5EN-HAA2HH03B-FLK User's Manual.
Superior spatter resistance.
Long Sensing-distance Models added for sensing,
distances up to 15 mm.
Pre-wired Smartclick Connector Models are also available. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / connector type.
Shape: shield, M12.
Detection range: 2mm.
Output configuration: NPN.
Action mode: NC. Fitting materials: Stainless steel (SUS304).
Count: 1 .
Accessories: Description, ps screws M3 × 8,
(with spring and plain washers);
Material, Stainless steel (SUS304);
Count, 2.
Applicable sensor (mounting pitch on sensor side): E3Z pre-wired model(25.4),
E32-R21 (for installation of E39-R3) (25.4).
Page: Dimensions, 11. Control output: relay output.
Auxiliary output: 2 points.
Heating wire break, SSR fault detection function: -.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E5EN-HAA2HH03B-FLK MANUAL.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E5EN-HAA2HH03B-FLK MANUAL.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).