OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-RTUAC100-240 Basic Type Manual E5CN-RTUAC100-240 Basic Type

OMRON E5CN-RTUAC100-240 Basic Type Manual E5CN-RTUAC100-240 Basic Type

Brand: OMRON
Product model: E5CN-RTUAC100-240
Name: E5CN-RTUAC100-240 Basic Type OMRON E5CN-RTUAC100-240 Basic Type Manual
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Size: M12 (Brass); Single; Shielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 6 E5CN-RTUAC100-240 Basic Type. 4 dia.
Protective tubing length L: 20 cm.
A Wide Variety of High-precision E5CN-RTUAC100-240
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-RTUAC100-240 Basic Type. Protective tubing length L: 50cm.
Protective tubing diameter: D = 6.4.
L2: 450 mm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E5CN-RTUAC100-240 Basic Type.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type.
Type: control output 2 point type (power AC/DC24V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performaance improvement E5CN-RTUAC100-240 Basic Type Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5CN-RTUAC100-240 Basic Type Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Power monitor
KM100-T-FLK AC100-240
OMRON Power monitor KM100-T-FLK AC100-240
Category: ontology power monitoring. Applica
OMRON
High-power Solid State Relays
G3PH-5075B AC100-240
OMRON High-power Solid State Relays G3PH-5075B AC100-240
Insulation method: Photocoupler. Operation i
OMRON
Time interval table
K3HB-PPB-L1AT11 AC100-240
OMRON Time interval table K3HB-PPB-L1AT11 AC100-240
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC21 AC100-240
Category: external supply 100mA DC10V. Input