Ontology: basic.
Size: 48 x 96mm.
Type: basic type (1 input)
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 point (pulse voltage + pulse voltage / current).
Output (SUB) points: 2 points.
Event entry point: 6.
Serial communication: RS-485.
High speed, high precision and multiple input and output universal digital regulator,
Liquid crystal display device with high visibility 5 bit and 3 line E5CN-RQ203L-FLK User's Manual
E5CN-RQ203L-FLK
The high speed sampling period is suitable for the operation of high speed response.
With a backlight liquid crystal display and the 3 display, can display the current value, the target value, the amount of operation.
1 digital controller can be multi point control / series control / proportion control E5CN-RQ203L-FLK User's Manual.
Standard is equipped with a variety of computing functions.
Equipped with DeviceNet communication function.
Data setting and data monitoring can be performed by means of a communication program. Appearance: Unshielded, M18.
Sensing distance: 10 mm.
Model: Operation mode, NO.
Proximity Sensor with a Long Screw Length.
Increased tightening strength E5CN-RQ203L-FLK User's Manual. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. E32-D25Y type: standard type; standard,
Specialty: plane shape (small) side,
Bending radius (mm): R10.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsSize: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CN-RQ203L-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CN-RQ203L-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.