OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-Q2HBTD-W Communications Functions Manual E5CN-Q2HBTD-W User's Manual

OMRON E5CN-Q2HBTD-W Communications Functions Manual E5CN-Q2HBTD-W User's Manual

Brand: OMRON
Product model: E5CN-Q2HBTD-W
Name: Digital Temperature Controller
Sort: User's Manual (Communications Functions)
File language: English
File size: 1.00MB
E3F3-R31M detection methods: Regression reflection type,
Wire lead out type,
Type: metal appearance; PNP output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyCase color: Black E5CN-Q2HBTD-W User's Manual.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard E5CN-Q2HBTD-W
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5CN-Q2HBTD-W User's Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-Q2HBTD-W User's Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvemennt E5CN-Q2HBTD-W Communications Functions Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CN-Q2HBTD-W Communications Functions Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Foundation type temperature controller
E5CN-Q2HBTD
OMRON Foundation type temperature controller E5CN-Q2HBTD
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-Q2HBT-W
OMRON Foundation type temperature controller E5CN-Q2HBT-W
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-QQ2HTD
OMRON Foundation type temperature controller E5CN-QQ2HTD
The main ody: terminal type, temperature inp
OMRON
Foundation type temperature controller
E5CN-QQ203T-FLK
OMRON Foundation type temperature controller E5CN-QQ203T-FLK
The main ody: terminal type, temperature inp