Appearance: M30.
Sensing distance: 10 mm.
Connection method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Polarity: Yes.
Operation mode : NC.
Pin arrangement: --.
Applicable connector code: --.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E E5CN-HV2BD Basic Type.
Standard Sensors for detecting ferrous metals
E5CN-HV2BD
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection E5CN-HV2BD Basic Type.
Cable protector provided as a standard feature. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: Yes.
Control output: Current output.
Previous mode: E5CZ-C2M.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs E5CN-HV2BD Basic Type.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protocol called Modbus is installed in the models,
with communications.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CN-HV2BD Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HV2BD Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.