OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTR2HH03D-FLK Manual E5CN-HTR2HH03D-FLK User's Manual

OMRON E5CN-HTR2HH03D-FLK Manual E5CN-HTR2HH03D-FLK User's Manual

Brand: OMRON
Product model: E5CN-HTR2HH03D-FLK
Name: Temperature Controller
Sort: User's Manual
File language: English
File size: 1.17MB
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP E5CN-HTR2HH03D-FLK User's Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5CN-HTR2HH03D-FLK Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5CN-HTR2HH03D-FLK User's Manual.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E5CN-HTR2HH03D-FLK User's Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (NPN output).
Output phases: Phases A, B, and Z.
Resolution (pulses/rotation): 100, 200, 360, 500.
Compact Encoder with External.
Diameter of 25 mm.
Incremental model.
External diameter of 25 mm.
Resolution of up to 500 ppr. Sensor type: Through-beam.
Sensing distance: 15 m.
Connection method: pre-wired. E5CN-HTR2HH03D-FLK Manual.
Model: NPN output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed forr special applications E5CN-HTR2HH03D-FLK Manual.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing.
Related products
OMRON
Programmed temperature controller
E5CN-HTR2BFD
OMRON Programmed temperature controller E5CN-HTR2BFD
Size: 48 48mm, terminal type. Type: control
OMRON
Programmed temperature controller
E5CN-HTR2HB
OMRON Programmed temperature controller E5CN-HTR2HB
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTR2BF
OMRON Programmed temperature controller E5CN-HTR2BF
Size: 48 48mm, terminal type. Category: con
OMRON
Programmed temperature controller
E5CN-HTR2HH03-FLK
OMRON Programmed temperature controller E5CN-HTR2HH03-FLK
Size: 48 48mm, terminal type. Category: con