Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5CN-HTR2H03-FLK USER'S MANUAL.
Ideal for the thermal input devices of Temperature Controllers
E5CN-HTR2H03-FLK
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5CN-HTR2H03-FLK USER'S MANUAL.
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5CN-HTR2H03-FLK USER'S MANUAL.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5CN-HTR2H03-FLK Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CN-HTR2H03-FLK Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.