OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5CN-HTQ2BFD Manual E5CN-HTQ2BFD Basic Type

OMRON E5CN-HTQ2BFD Manual E5CN-HTQ2BFD Basic Type

Brand: OMRON
Product model: E5CN-HTQ2BFD
Name: E5CN-HTQ2BFD Manual OMRON Digital Temperature Controller E5CN-HTQ2BFD Basic Type
Sort: Basic Type
File language: English
File size: 6.25MB
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points E5CN-HTQ2BFD Basic Type.
Communication: RS-485.
Event input: 6 points.
Remote SP input: there E5CN-HTQ2BFD
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E5CN-HTQ2BFD Basic Type.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E5CN-HTQ2BFD Basic Type.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5CN-HTQ2BFD Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products
OMRON
High performance temperature controller
E5CN-HV201D-FLK
OMRON High performance temperature controller E5CN-HV201D-FLK
Size: 48 x 48mm. Body: terminal type. Type: c
OMRON
Programmed temperature controller
E5CN-HTQ2H01-FLK
OMRON Programmed temperature controller E5CN-HTQ2H01-FLK
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HQ2BF
OMRON High performance temperature controller E5CN-HQ2BF
Size: 48 x 48mm. Body: terminal type. Categor
OMRON
High performance temperature controller
E5CN-HQ2H03-W-FLK
OMRON High performance temperature controller E5CN-HQ2H03-W-FLK
Size: 48 x 48mm. Body: terminal type. Categor