Name: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4 E5CN-HQ2M-500 User's Manual.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-485;
or RS-232C, selectable
E5CN-HQ2M-500
Input type: No input.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups E5CN-HQ2M-500 User's Manual.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models.).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise E5CN-HQ2M-500 User's Manual. Appearance: Unshielded, M30.
Sensing distance: 18 mm.
Model: Operation mode, NO.
Proximity Sensor with a Long Screw Length.
Increased tightening strength. Cable protectors,
provided as a standard feature.
Increased indicator visibility.
A milled section for wrench grip on all models. Size: M8(Stainless steel)(See note 2.); Single; Shielded.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (aauto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-HQ2M-500 Communications Functions MANUAL.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-HQ2M-500 Communications Functions MANUAL.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.