Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AZ-C3MLD User's Manual.
Ideal for the thermal input devices of Temperature Controllers
E5AZ-C3MLD
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control E5AZ-C3MLD User's Manual.
Outputs(control/transfer): 4 points: Pulse voltage and Pulse,
voltage/current and Current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response E5AZ-C3MLD User's Manual.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Transistor output: 2 points(sourcing).
Auxiliary output: None.
Functions: Heater burnout alarm, 2 (See note 3.); Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control ffor up to 2 groups E5AZ-C3MLD Manual.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5AZ-C3MLD Manual. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.