OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5AR-TQ4B Manual E5AR-TQ4B OPERATION MANUAL

OMRON E5AR-TQ4B Manual E5AR-TQ4B OPERATION MANUAL

Brand: OMRON
Product model: E5AR-TQ4B
Name: PLC Module
Sort: OPERATION MANUAL
File language: English
File size: 3.69MB
Appearance: Shielded, M30.
Sensing distance: 8 mm.
Output configuration: DC 2-wire.
Model: Operation mode, NC.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available E5AR-TQ4B OPERATION MANUAL. Case color: Black.
Control output: Voltage output (for driving SSR) E5AR-TQ4B
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5AR-TQ4B OPERATION MANUAL.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5AR-TQ4B OPERATION MANUAL.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of tthe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AR-TQ4B Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AR-TQ4B Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Programmable Digital Controller
E5AR-TQQE3MWW-FLK
OMRON Programmable Digital Controller E5AR-TQQE3MWW-FLK
Size: 96 × 96 mm. Control type: 4-loop contr
OMRON
Programmable Digital Controller
E5AR-TC4B
OMRON Programmable Digital Controller E5AR-TC4B
Size: 96 × 96 mm. Control type: Basic contro
OMRON
Digital Controllers
E5AR-Q43DB-FLK
OMRON Digital Controllers E5AR-Q43DB-FLK
Size: 96 × 96 mm. Control type: Basic contro
OMRON
Programmable Digital Controller
E5AR-T Series/E5ER-T Series
OMRON Programmable Digital Controller E5AR-T Series/E5ER-T Series
A new High-speed, High-precision Digital. Co