Name: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) (See note 2 E5AN-HAA2HH01B-W-FLK User's Manual. ).
Auxiliary output: None.
Functions: Heater burnout alarm, None; Event inputs, None
E5AN-HAA2HH01B-W-FLK
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature E5AN-HAA2HH01B-W-FLK User's Manual.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5AN-HAA2HH01B-W-FLK User's Manual. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise. Appearance: Shielded, M12.
Sensing distance: 2 mm.
Output: NPN.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Appearance: Shielded, M8.
Sensing distance: 2 mm.
Model: Output configuration: NPN NC.
Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
with reduced problems due to workpiece collisions.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature. Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC100 ~ 240V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP iinput, suitable for a wide range of applications E5AN-HAA2HH01B-W-FLK Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperrature controller is connected to each other by using the component communication E5AN-HAA2HH01B-W-FLK Manual.
A new type of proportional control allows you to control the valve.