OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5AN-HAA2HBM-500 Basic Type Manual E5AN-HAA2HBM-500 Basic Type

OMRON E5AN-HAA2HBM-500 Basic Type Manual E5AN-HAA2HBM-500 Basic Type

Brand: OMRON
Product model: E5AN-HAA2HBM-500
Name: E5AN-HAA2HBM-500 Basic Type OMRON E5AN-HAA2HBM-500 Basic Type Manual
Sort: Basic Type (Basic Type)
File language: English
File size: 6.14MB
Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485 E5AN-HAA2HBM-500 Basic Type.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5AN-HAA2HBM-500
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance E5AN-HAA2HBM-500 Basic Type.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set E5AN-HAA2HBM-500 Basic Type.
It can be easily set by CS-Thermo (sold separately). Power: AC.
Purpose: general purpose type.
Amplifier unitName: Basic Unit(gradient temperature control)(See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 4.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive)(See note 2.).
Control outputs 3 and 4: Voltage output: 2 points (for SSR drive) (See note 2.).
Auxiliary output: None.
Functions: Heater burnout alarm, None; Event inputs, None.
Communications functions: G3ZA connection port,
RS-485 From End Unit, Port A, RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groupps E5AN-HAA2HBM-500 Basic Type Manual.
Set gradient temperature control or 2-PID control for each group.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5AN-HAA2HBM-500 Basic Type Manual. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.
Related products