Classification: Exclusive Models.
Description: Used for room temperature measurement.
Temperature range (See note 3.): -50°C to 60°C .
Element type: Pt100.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 40.
A Wide Variety of High-precision E5AC-TCX4DSM-064 Instructions Manual.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E5AC-TCX4DSM-064
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AC-TCX4DSM-064 Instructions Manual. E32-T11F type: resistant to environmental type; resistant to drugs,
Specialty: Teflon coated spherical probe,
Shape / detection distance (mm): 2500; 2000; 1300; (520),
Bending radius (mm): R4.
Standard test object (minimum test object) (mm) 1: 4 (0.1),
Fiber element for meeting diversified needsName: HFU (gradient temperature control) (See note 1.).
Power supply voltage: 24 VDC supplied from the End Unit E5AC-TCX4DSM-064 Instructions Manual.
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sourcing).
Functions: Heater burnout alarm, None; Event inputs, 4.
Communications functions: From End Unit, Port A, RS-485; Port C, RS-485;
or RS-232C, selectable.
Input type: No input.
Terminal: Screw-less clamp.
Gradient Temperature Control to Achieve.
Consistent Layer Temperature.
Perform gradient temperature control ranging from 2 to 32 channels.
Perform 2-channel gradient temperature control for up to 16,
groups, or 32-channel gradient temperature control for up to 2 groups.
Sett gradient temperature control or 2-PID control for each group E5AC-TCX4DSM-064 RS-485 CompoWay/F Manual.
Reduce design work for ladder programming with programless,
connections to Programmable Controllers. (The same feature,
as Standard-control EJ1 Models E5AC-TCX4DSM-064 RS-485 CompoWay/F Manual. ).
Connect directly to the G3ZA Multi-channel Power Controller,
using optimum cycle control for high-accuracy control with minimal noise.