OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E5AC-CX4DSM-014 RS-485 CompoWay/F Manual E5AC-CX4DSM-014 lnstruction Manual

OMRON E5AC-CX4DSM-014 RS-485 CompoWay/F Manual E5AC-CX4DSM-014 lnstruction Manual

Brand: OMRON
Product model: E5AC-CX4DSM-014
Name: Digital Counter
Sort: lnstruction Manual (RS-485 CompoWay/F)
File language: English
File size: 2.32MB
Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- E5AC-CX4DSM-014 lnstruction Manual E5AC-CX4DSM-014
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 E5AC-CX4DSM-014 lnstruction Manual. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors E5AC-CX4DSM-014 lnstruction Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Appearance: Shielded, 8 dia.
Stable sensing distance: 2 mm.
Proximity Sensor with Separate.
Amplifier Unit for Detection of.
Non-ferrous Metals with Simple.
Sensitivity Adjustment.
Detects aluminum, copper, and other non-ferrous metals.
Product lineup includes compact, flat Sensor Head (E2CY-V3A) and,
model with fluororesin (E2CY-C2AF) for resistance to chemicals.
Simple teaching function to easily adjust sensitivity.
Check detection status at a glance with numeric values on a digital display. Ontology: terminal type, analog input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance iimprovement E5AC-CX4DSM-014 RS-485 CompoWay/F Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV E5AC-CX4DSM-014 RS-485 CompoWay/F Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5AC-CX2DSM-014
OMRON Digital temperature controller E5AC-CX2DSM-014
Size: 96 x 96mm. Control output 1: linear cu
OMRON
Digital Temperature Controller
E5AC-CX1ASM-800
OMRON Digital Temperature Controller E5AC-CX1ASM-800
Control output 1: Linear current output. Con
OMRON
Digital Temperature Controller
E5AC-CX1DSM-800
OMRON Digital Temperature Controller E5AC-CX1DSM-800
Control output 1: Linear current output. Con
OMRON
Digital temperature controller
E5AC-CX4DSM-014
OMRON Digital temperature controller E5AC-CX4DSM-014
Size: 96 x 96mm. Control output 1: linear cu