Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 15cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5AC-CX2DSM-004 User's Manual.
Ideal for the thermal input devices of Temperature Controllers
E5AC-CX2DSM-004
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type E5AC-CX2DSM-004 User's Manual.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: shield, M30.
Detection range: 10mm.
Output configuration: PNP.
Action mode: NO. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: shield, M18.
Detection range: 5mm.
Output configuration: NPN E5AC-CX2DSM-004 User's Manual.
Action mode: NC. Size: DIN 1/4, 96 x 96 x 78mm.
Power supply voltage: AC100 ~ 240V.
Alarm points: 3 points.
Control output: voltage output (for driving a bidirectional thyristor switching element).
Input: Platinum resistance.
New generation intelligent general temperature controller.
The thickness is only 78 mm.
Various temperature inputs: thermocouple, platinum resistance, non contact temperature sensor signal input.
Automatic adjustment and self adjustment.
Automatic adjustment can be performed even when the self adjustment is being performed.
Can use heating or heating / cooling control.
Event entry allows multiple SP options and run / stop functions. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5AC-CX2DSM-004 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5AC-CX2DSM-004 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.