C200H A Backplane I/O Mounting Bracket For 8 Slots C200H-ATTA3.Power supply voltage: 100 to 240VAC.
Output capacity: 5-VDC output capacity, 2.8A;
24-VDC output capacity, 0.4A;
Total power consumption, 14w.
Options: 24-VDC service power supply, No;
RUN output, No; Maintenance forecast monitor, No CVM1-CPU21-EV2 Macro Reference.
Standards: UC1, N, L, CE.
Equipped with the RUN output for,
checking the operation status,
as well as the replacement
CVM1-CPU21-EV2
notification function for easy,
maintenance.
Lineup of five models including the,
AC power supply (25W).
Stable power supply is available from the,
CJ-series CPU Unit to each I/O Units via the,
dedicated bus. The most suitable Power Supply,
Unit can be selected among various I/O ,
specifications and/or options CVM1-CPU21-EV2 Macro Reference. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system CVM1-CPU21-EV2 Macro Reference.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 18 points.
Outputs points: 12 points.Model: C200H-ID211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VDC, +10%/–15%.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: 10mUnit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Link supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required CVM1-CPU21-EV2 Cv Support Sortware Version 2: Offline Manual.
With Wired Controller Link Units,
systeems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable CVM1-CPU21-EV2 Cv Support Sortware Version 2: Offline Manual.