Unit type: CJ1 Basic I/O Units.
Product name: Quick-response Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block CJ1W-SCU41-V1 HOST CONNECTION MANUAL.
No. of words allocated: 1 word
CJ1W-SCU41-V1
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
Capture Input Signals Shorter,
Than the Cycle Time.
This Input Unit can read pulse inputs that,
are shorter than the cycle time of the CPU Unit. C500-DA/3G2A5-DA Special I/O Unit Analog Output C500-DA001(3G2A5-DA001).
Output: 2 pts.
Specification: +1~+5V、4~20mA CJ1W-SCU41-V1 HOST CONNECTION MANUAL. Name: CompoBus/S Master Module.
Model: C200HW-SRM21-V1.
Communications protocol: Dedicated CompoBus/S protocol.
CompoBus/S Master Unit
High-speed ON/OFF Bus Saving Wiring Effort and Manufacturing Steps in Factories.Specifications: 8 Kwords without clock.Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 outputs(High speed);
Maximum switching capacity, 24VDC, 0 CJ1W-SCU41-V1 HOST CONNECTION MANUAL. 5A;
Commons, 16 points, 1 common;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.15A; 24V, --.
Standards: N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Unit classifi cation: CS1 CPU Bus Unit.
Product name:Controller Link Unit.
Specifications: Communications cable,
Optical ring GI cabl;
Communications type, Data links and,
message service; Duplex support,
Yes. Unit duplexing and cable loop,
back are supported.
Max. Units mountable per CPU Unit,
Non-duplex: 8, Duplex: 11 (6 Units,
comprising 3 sets of Duplex Units,
+ 5 Non-duplex Units).
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.65A; 26V, --.
Standards: UC1, N, L, CE.
New Controller Link Units,
Now with 4,000 Send Words.
The Controller Link is an,
FA network that can send,
and receive large amounts,
of data easily and at high speed.
The Controller Linkk supports data,
links that enable sharing data between,
PLCs and computers and a message service,
that enables sending and receiving,
data whenever required CJ1W-SCU41-V1 Communications Commands Manual.
With Wired Controller Link Units,
systeems can be flexibly built by using,
Repeater Units to enable T branches,
long-distance wiring, and converting,
part of the network to optical cable CJ1W-SCU41-V1 Communications Commands Manual.