OMRON
Home >> Download >> OMRON >> Catalog Download >> OMRON SRT2-ROF16 datasheet PDF catalog SRT2-ROF16 PDF datasheet

OMRON SRT2-ROF16 datasheet PDF catalog SRT2-ROF16 PDF datasheet

Brand: OMRON
Product model: SRT2-ROF16
Name: Relay-mounted Remote I/O Terminals
Sort: PDF datasheet
File language: English
File size: 5.91MB
Power ratings: 60 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 12 V.
Output current: 4.5 A.
Boost Current: 5.4 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market SRT2-ROF16 PDF datasheet.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC) SRT2-ROF16
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16 SRT2-ROF16 PDF datasheet.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 3.75 A.
UL Class 2 Output standards: -- SRT2-ROF16 PDF datasheet.
Model number(screw terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.) Power ratings: 60 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 2.5 A.
UL Class 2 Output standards: Yes.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
Neww models with screwless terminal blocks and,
indication monitor SRT2-ROF16 datasheet PDF catalog.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) SRT2-ROF16 datasheet PDF catalog.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Sensor Terminals
SRT2-ID08S
OMRON Sensor Terminals SRT2-ID08S
Classification: For input. Internal I/O circ
OMRON
Waterproof Terminals
SRT2-ID04CL
OMRON Waterproof Terminals SRT2-ID04CL
Input/Output: Inputs. Internal I/O circuit
OMRON
Analog Input Terminal
SRT2-AD04
OMRON Analog Input Terminal SRT2-AD04
Classification: Analog Input Terminal. I/O