Control power supply voltage: 100/110 VAC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) S8FS-C01524J PDF datasheet.
Detect three-phase AC current for under and/or overcur,
rent using current converter
S8FS-C01524J
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) S8FS-C01524J PDF datasheet.
LED operation indicator.
UL/CSA approval (SDV-F@). Input voltage: 24 to 28 VDC.
Output voltage: 24 V.
Output current: 3.7 A/8 A (See note 2.).
DC Backup Block for S8TS Prevents 24-VDC.
Outages Due to Power Interruptions or Failures.
Supplies 24 VDC for a fixed period of time even during.
AC input outages to considerably improve system reliability S8FS-C01524J PDF datasheet.
Block Power Supply Basic Block is connected using a Bus Line.
Connector to achieve a simple system configuration.
Notification of alarms is provided by indications on the main unit.
and alarm signal output.
RoHS-Compliant. Category: incidental cover type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 15V.
Output current: 10A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch pprotection to prevent electric shock S8FS-C01524J datasheet PDF catalog.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whenn the fan is replaced by the customer S8FS-C01524J datasheet PDF catalog. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"