Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Communication: RS-485; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes K8AK-AW1 100-240VAC PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K8AK-AW1 100-240VAC
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DProduct: Straight Bar Nozzle; 300 mm.
Wide Range of Nozzles for Optimal K8AK-AW1 100-240VAC PDF datasheet.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt K8AK-AW1 100-240VAC PDF datasheet.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR and MCCBB is simple K8AK-AW1 100-240VAC datasheet PDF catalog.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display oof the accident occurrence phase is used to facilitate the inspection after the accident K8AK-AW1 100-240VAC datasheet PDF catalog.
Reduce the consumption of VA, reduce the burden of converter.
Related products
OMRON
K8AK-TH11S 100-240VAC
OMRON  K8AK-TH11S 100-240VAC
Power supply voltage: 100 to 240 VAC. Type:
OMRON
Single-phase Current Relay
K8AK-AS3 100-240VAC
OMRON Single-phase Current Relay K8AK-AS3 100-240VAC
Setting range: 10 to 100 A AC, 20 to 200 A AC
OMRON
Conductive Level Controller
K8AK-LS 100-240VAC
OMRON Conductive Level Controller K8AK-LS 100-240VAC
Power supply voltage: 100 to 240 VAC. Ideal
OMRON
K8AK-TH12S 100-240VAC
OMRON  K8AK-TH12S 100-240VAC
Power supply voltage: 100 to 240 VAC. Type: